Nominal sensing distance | 0,5 … 3 m |
Resolution | 500mm |
controlled height | 500 mm |
number of rays | 2 |
Sensitivity adjustment | Dip-switch |
Effective Aperture Angle | ≤ ±2,5° |
Function Principle | Transceiver (Active side) |
Available functions | Manual/Automatic Restart, EDM, T Muting, Override, Muting Enable, Muting Filter |
Description | Big RRX active unit T arms |
Functions | Body protection 2 beams muting |
Type | Type 4 safety light curtain (A/M) |
SIL | 3 |
SILCL | 3 |
PL | e |
PFHd | 8,57E-09 |
MTTFd | 439 years |
SFF | 97,50% |
Output type | 2 x PNP-NO (OSSD safety output) with EDM |
Response time | 11 ms |
Operating Voltage | 24 Vdc ± 20% |
Load current | ≤ 500mA each output |
Emission | Infrared LED (950 nm wavelength) |
Interference to external light | According to IEC 61496-2 |
Power Consumption - Receiver | ≤ 6,5W (no load) |
Power Consumption - Emitter | n/a |
Cabel Length (Power Supply/Output) | ≤ 70m |
Dimensions | 52x57x609 |
Connections | M12-12 poles + M12-5 poles (Active Unit) |
Storage temperature | -25…+ 70°C |
Material | Painted aluminum / PMMA / PBT Valox 508 |
Vibrations | Width 0.35 mm, frequency 10 … 55Hz; 20 sweep per axis, 1octave/min (EN 60068-2-6) |
Shocks | 16 ms (10 G) 1,000 shocks per axis (EN 60068-2-29) |
EMC compatibility | According to 2014/30/EU Directive |
Dimensions | 52x56,9x609,35 mm |
Operating Temperature | 0…+55°C |
Humidity | 15 … 95 % (no condensation) |
Mechanical Protection | IP65 |