Basic

95B067200

IS-12-E9-03
Inductive Proximity Sensor ø12 standard - double range flush 4 mm - 2 wire dc no/nc 2 wires - 2m cable

Non-contact detection Cost effective and reliable detection of any metal part

Overview

  • Standard proximity M4, M5, M8, M12, M18, M30
  • Double range (i.e. M12 4mm, M18 14mm, M30
  • 20mm)
  • Unshielded or shielded models for flush mounting
  • Nickel brass or stainless steel short and long
  • housing
  • Ecolab and Diversey certifications for industrial
  • detergents
  • Multi-voltage, Metal face, Weld field immune models
  • NO/NC, NPN or PNP output and programmable
  • versions.

Technical Features

Detection properties
Nominal sensing distance 4mm
Operanting distance 0…3,24mm
Standard target 12x12mm FE360
Correction Factor copper: 0,2…0,5 / aluminium: 0,3…0,5 / brass: 0,4…0,6 / stainelss steel: 0,7…0,9
Repeat Accuracy < 3% (UB 24V Ta=23°C ±5°C)
Hysteresis < 10%
Application
Description M12 standard flush mount
Functions Proximity
Outputs
Output type NPN/PNP
Output Function NO/NC
Switching frequency 200Hz
Response time 2,5
Electrical data
Operating Voltage 10...30Vdc
No-Load supply current < 1,6mA
Load current > 1,6 … 100mA
Output voltage drop ≤ 6,5V
Max ripple content ≤ 10%
LED indicators Yellow LED output state
Time delay before availability ≤ 75ms
Short-circuit protection Yes
Reverse Polarity Protection Yes
Emission ≥100kHz
Protection against inductive loads Yes
Mechanical data
Mounting Shielded
Dimensions Ø12x59
Housing Material Nickel-plated brass
Connections 2m PVC Cable
Active Head Material LCP
Tightening torque 6Nm
Material Nickel-plated brass
Diameter/Dimension M12
Test/Approvals
Approvals CE cULus
Accessories
Supplied Accessories 2 nuts M12x1
Generical Data
Dimensions Ø12 / L = 59mm
Operating Temperature -25°C…+70°C
Mechanical Protection IP67

Downloads for IS-12-E9-03